L, if you already have a pressure array, and your
Temperature data is on pressure levels, then you can
skip the first part where we convert T from hybrid to pressure levels and
just calculate potential temperature using your pressure array
e.g.
theta = T_on_pressure_levels*(100000/pressure_array)^0.286
the rest should be the same.
sm
--****************************************************** Sylvia Murphy EML: murphys AT ucar.edu NCAR CGD/CSEG PHN: 303-497-1720 1850 Table Mesa Drive FAX: 303-497-1333 Boulder CO 80305
WEB: http://www.cgd.ucar.edu/csm/support/ http://www.cgd.ucar.edu/csm/support/CSM_Graphics/ ******************************************************
_______________________________________________ ncl-talk mailing list ncl-talk AT ucar.edu http://mailman.ucar.edu/mailman/listinfo/ncl-talk