Re: missing value in function "eofunc_varimax"

From: Dennis Shea <shea_at_nyahnyahspammersnyahnyah>
Date: Sun, 17 Dec 2006 13:49:40 -0700 (MST)

> I want to use the function "eofunc_varimax" to get rotated EOFS, but I
> got the following message:
>
> fatal: eofunc_varimax: The input array contains missing values.
> However, the instruction in the web page say Missing values are ignored.
>
> http://www.ncl.ucar.edu/Document/Functions/Built-in/eofunc_varimax.shtml
>
> So I wonder where is the problem. Besides, I am using NCL Version
> 4.2.0.a03464-bit on Linux.
--------------------------------

Aploogies for the late response.

You are correct. The documentation states that missing values
can be included. Unfortunately, the code was inadvertently
not included. It will be in the next release of NCL [a035]. Sorry.

Note: the function still does not return the percent variance
explained after rotation.

 
_______________________________________________
ncl-talk mailing list
ncl-talk_at_ucar.edu
http://mailman.ucar.edu/mailman/listinfo/ncl-talk