Re: skewt plot

From: Dennis Shea <shea_at_nyahnyahspammersnyahnyah>
Date: Fri Sep 30 2011 - 15:02:04 MDT

You might try the attached. The resulting data could
be input to the skewT. This does not merge the data
so it is in ascending order.

On 9/30/11 9:04 AM, priyanka roy wrote:
> Hello ,
>
> I am trying to plot the skewt-log p plot at a particular station using
> the code http://dss.ucar.edu/datasets/ds337.0/software/skewt_station.ncl
> I have made the modifications for using u and v instead of wspd and
> direction, however the pressures of wind and temp are not same. How
> should I create a single pressure array for both.
>
> Thanks
> Priyanka
>
> The pressures at which u and v are measured are:
> (0) 978
> (1) 688.5
> (2) 663.9
> (3) 639.9
> (4) 616.5
> (5) 593.8
> (6) 571.7
> (7) 509
>
> The pressures at which temperatures are measured are :
> (0) 978
> (1) 963
> (2) 925
> (3) 906
> (4) 863
> (5) 850
> (6) 750
> (7) 740
> (8) 737
> (9) 700
> (10) 650
> (11) 580
> (12) 505
> (13) 500
> (14) 433
> (15) 400
> (16) 302
> (17) 300
> (18) 250
> (19) 203
> (20) 200
> (21) 186
> (22) 150
> (23) 136
> (24) 133
> (25) 125
> (26) 122
> (27) 111
> (28) 110
> (29) 100
> (30) 94.7
> (31) 88.7
> (32) 83.7
> (33) 70
> (34) 67.7
> (35) 65.9
> (36) 58.7
> (37) 54.1
> (38) 50
> (39) 45.8
> (40) 39.5
> (41) 38.4
> (42) 30
> (43) 29.7
> (44) 27.7
> (45) 25.6
> (46) 23.8
> (47) 21.4
> (48) 20.8
> (49) 20
> (50) 18.3
> (51) 17
> (52) 16.2
>
>
>
> _______________________________________________
> ncl-talk mailing list
> List instructions, subscriber options, unsubscribe:
> http://mailman.ucar.edu/mailman/listinfo/ncl-talk

_______________________________________________
ncl-talk mailing list
List instructions, subscriber options, unsubscribe:
http://mailman.ucar.edu/mailman/listinfo/ncl-talk

Received on Fri Sep 30 15:02:09 2011