The original fortran function documentation says that mixing ratio
is the correct input.
Regards
D
On 02/19/2010 01:04 PM, Maurice.McHugh@noaa.gov wrote:
> Good afternoon everyone!
>
> I'd like to use the relhum function (http://www.ncl.ucar.edu/Document/Functions/Built-in/relhum.shtml) to calculate relative humidity (rh) given temperature (t), specific humidity (q) and pressure (p).
>
> The examples shown all use q (specific humidity), rather than the mixing ratio (MR) as is stated at the top of the examples page.
>
> While I can easily convert q to MR (MR = q/(1-q) ), I'd like some clarification as to whether q or MR are required to produce the correct RH.
>
> Thank you,
>
> Maurice
>
>
> _______________________________________________
> ncl-talk mailing list
> List instructions, subscriber options, unsubscribe:
> http://mailman.ucar.edu/mailman/listinfo/ncl-talk
-- ====================================================== Dennis J. Shea tel: 303-497-1361 | P.O. Box 3000 fax: 303-497-1333 | Climate Analysis Section | Climate & Global Dynamics Div. | National Center for Atmospheric Research | Boulder, CO 80307 | USA email: shea 'at' ucar.edu | ====================================================== _______________________________________________ ncl-talk mailing list List instructions, subscriber options, unsubscribe: http://mailman.ucar.edu/mailman/listinfo/ncl-talkReceived on Fri Feb 19 14:18:41 2010