Re: tolerance parameter for poisson_grid_fill()

From: Dennis Shea <shea_at_nyahnyahspammersnyahnyah>
Date: Mon Nov 29 2010 - 16:58:05 MST

Basically, multiple passes are made over the grid space.
When successive iterations yield a difference less that
the tolerance, the passes are terminated.

"variable dependent": Depending on the ultimate goal a high
or low tolerance could be used. For, say, geopotential height the
tolerance may could be larger than (say) specific humidity.

On 11/29/10 4:33 PM, Rob Nicholas wrote:
> Could someone offer an explanation of the "tolerance" parameter used
> by the poisson_grid_fill() function? The documentation mentions that
> it's "variable dependent" but doesn't offer any further details. Any
> recommendations on how to decide what to use here?
>
> Thanks!
> Rob
> _______________________________________________
> ncl-talk mailing list
> List instructions, subscriber options, unsubscribe:
> http://mailman.ucar.edu/mailman/listinfo/ncl-talk
_______________________________________________
ncl-talk mailing list
List instructions, subscriber options, unsubscribe:
http://mailman.ucar.edu/mailman/listinfo/ncl-talk
Received on Mon Nov 29 16:58:11 2010

This archive was generated by hypermail 2.1.8 : Tue Nov 30 2010 - 08:26:08 MST