Basically, multiple passes are made over the grid space.
When successive iterations yield a difference less that
the tolerance, the passes are terminated.
"variable dependent": Depending on the ultimate goal a high
or low tolerance could be used. For, say, geopotential height the
tolerance may could be larger than (say) specific humidity.
On 11/29/10 4:33 PM, Rob Nicholas wrote:
> Could someone offer an explanation of the "tolerance" parameter used
> by the poisson_grid_fill() function? The documentation mentions that
> it's "variable dependent" but doesn't offer any further details. Any
> recommendations on how to decide what to use here?
>
> Thanks!
> Rob
> _______________________________________________
> ncl-talk mailing list
> List instructions, subscriber options, unsubscribe:
> http://mailman.ucar.edu/mailman/listinfo/ncl-talk