Re: About function smthClmDayTLL

From: Dennis Shea <shea_at_nyahnyahspammersnyahnyah>
Date: Fri Oct 18 2013 - 13:04:51 MDT

   HighFreq = OriginalData - smthClmDayTLL

Will give you the high frequenncy data.

On 10/18/13 12:34 PM, Waqar Younas wrote:
> Hi everyone,
> I am working on MJO analysis where we require to remove the time mean and
> first three harmonics from the data for further analysis. I noticed that
> the NCL function smthClmDayTLL retains the number of harmonics which means
> if we set nhar= 4 it will retain the first 4 harmonics in the data and set
> zero all others. Is there any method where i can remove first three or four
> harmonics from the data instead of retaining them? Any help will be greatly
> appreciable.
> Thanks.
>
>
>
>
> _______________________________________________
> ncl-talk mailing list
> List instructions, subscriber options, unsubscribe:
> http://mailman.ucar.edu/mailman/listinfo/ncl-talk
>